File handles projects, imports and portable packs. Edit handles undo/redo. Project opens project-level settings. Calculation runs design calculation, sizing and optimization. Tools opens parameter studies, Monte Carlo and TRT evaluation. View controls theme, graphics, text size and CSV format. Help opens these offline pages and licence notices. Toolbar buttons perform the same actions as their menu entries.

F1 opens help for the selected page or active dialog. F5 Calculate; F6 Size length; F7 Optimize; F8 Parameter study; F9 Monte Carlo; Ctrl+PgUp/PgDn changes page; Alt+0 focuses the input tree. Save before closing. Esc or Cancel requests cancellation where supported.

ActionOperationShortcut
2D design2D design
3D analysis3D analysis
About BoreThermAbout BoreTherm
About QtAbout Qt
ArrangeArrange the blocks from left to right along the connections.
Automatic (as the number format)German number format: Excel (German); otherwise international.
Automatic (software OpenGL in remote sessions)Automatic (software OpenGL in remote sessions)
BTESBTES
Bentonite (0.8 W/(m·K))Bentonite (0.8 W/(m·K))
Borehole fieldAdd the borehole field of this project (at most one per system).
Built-inBuilt-in
Buried partThe buried part above each borehole head (dashed).
CSV formatCSV format
CalculateSimulate the mean fluid temperature over the design period (F5)F5
CalculationCalculation
Cement–bentonite (1.1 W/(m·K))Cement–bentonite (1.1 W/(m·K))
Clear listClear list
Co-simulation previewCo-simulation preview
Coaxial 63 × 5.8 / 40 × 3.7 mm, borehole Ø 152 mmPE 100 pipes, thermally enhanced grout (λ 2.0 W/(m·K)). Typical values; check them against the product data.
ConstantAdd a source with a constant value.
DarkDark
DeleteDelete the selected blocks and connections (Del).
Design valueDesign value
DeutschDeutsch
Double U 32 × 2.9 mm, borehole Ø 152 mmPE 100 pipes, thermally enhanced grout (λ 2.0 W/(m·K)). Typical values; check them against the product data.
Double U 40 × 3.7 mm, borehole Ø 180 mmPE 100 pipes, thermally enhanced grout (λ 2.0 W/(m·K)). Typical values; check them against the product data.
Drilling areaDrilling area
EastView from the east, looking west.
EditEdit
Energy pile Ø 1200 mm, 4 U-tubes 32 × 2.9 mmEnergy pile: concrete λ 1.8 W/(m·K), C 2.2 MJ/(m³·K), PE 100 pipes on the reinforcement cage (75 mm cover). Use the short-time borehole model. Typical values; check them against the pile design.
Energy pile Ø 600 mm, double U 32 × 2.9 mmEnergy pile: concrete λ 1.8 W/(m·K), C 2.2 MJ/(m³·K), PE 100 pipes on the reinforcement cage (75 mm cover). Use the short-time borehole model. Typical values; check them against the pile design.
Energy pile Ø 600 mm, helix 25 × 2.3 mm, pitch 250 mmEnergy pile: concrete λ 1.8 W/(m·K), C 2.2 MJ/(m³·K), PE 100 pipes on the reinforcement cage (75 mm cover). Use the short-time borehole model. Typical values; check them against the pile design.
EnglishEnglish
Ethanol 24 %Ethanol 24 %
Examples and getting startedExamples and getting started
Excel (German): separator ; and decimal commaOpens directly in a German Excel: cells separated by semicolons, numbers like 2,35.
ExitExit
Export FMU…Write the borehole field as an FMI 2.0 Co-Simulation FMU for system simulation tools (Modelica tools, OMSimulator, Python)
Export PDF report…Write a PDF report with inputs, results and charts (saved report profile)Ctrl+P
Export as PNG…Export as PNG
Export as SVG…Export as SVG
Export results (CSV)…Write the monthly (and hourly) results as CSV
FMU…Add a Co-Simulation FMU (FMI 2.0, 64-bit Windows). You can also drag .fmu files onto the diagram.
FileFile
FitShow the whole diagram (Ctrl+0).
Focus input treeFocus input treeAlt+0
Full FEM: groundwater flow and heat (TH)Full FEM: groundwater flow and heat (TH)
Full FEM: transient boreholesFull FEM: transient boreholes
Germany 2026 (indicative)Indicative net prices from public sources (2026), not a quote.
GraphicsGraphics
Ground layersThe ground layers as translucent slabs with their names.
Grout λGrout λ
Guided examplesGuided examples
HelpHelp
Help contentsHelp contents
Help for this pageHelp for this pageF1
Import legacy project file…Import a legacy project file (.dat) with the classic-method compatibility options switched onCtrl+I
Inclined boreholesInclined boreholes
Insulated casing (top 0–10 m)An insulated casing (PE foam, λ = 0.038 W/(m·K), up to 10 mm) from the surface to 10 m: limits the heat exchange near the surface, e.g. under a building or near utilities.
Insulated return leg (top 30 %)Sleeves (PE foam, up to 10 mm) on the up-going legs over the top 30 % of the active length, against the thermal short-circuit between the legs.Effective for coaxial and deep boreholes and at low flow; at ordinary single-U flows Rb* can rise, because the return leg also exchanges less heat with the ground. Compare Rb* after a calculation.
Insulation λInsulation λ
International: separator , and decimal pointFor scripts and English software: cells separated by commas, numbers like 2.35.
IsometricOblique view from the south-west (also: Home key).
LanguageLanguage
LargeLarge
LargerLargerCtrl+=
Larger diameter at the topThe top of the borehole, from the surface to D + 10 % of H, drilled 50 mm wider, e.g. through the overburden or a cased section.
Layered ground and groundwaterLayered ground and groundwater
LightLight
MainMain
Monoethylene glycol (MEG) 25 %Monoethylene glycol (MEG) 25 %
Monoethylene glycol (MEG) 33 %Monoethylene glycol (MEG) 33 %
Monopropylene glycol (MPG) 25 %Monopropylene glycol (MPG) 25 %
Monopropylene glycol (MPG) 33 %Monopropylene glycol (MPG) 33 %
Monte CarloMonte Carlo
Monte Carlo…Size (or simulate) for random samples of uncertain inputs: length at 95 % confidence and the inputs that matter most (F9)F9
My designsMy designs
My fluidsMy fluids
My price listsMy price lists
NewStart a new project with default valuesCtrl+N
New from exampleOffice building example: 4×4 field, 150 m, single-U 32 mm, 25 % MPG, 200 MWh/year heating, 45 MWh/year cooling
Next pageNext pageCtrl+PgDown
No-go zoneNo-go zone
NormalNormal
Open recentOpen recent
Open the library folderOpen the library folder
Open…Open a BoreTherm project (.boretherm) or a legacy project file (.dat)Ctrl+O
OptimizationOptimization
Optimize…Find the shortest / cheapest layout on a given plot (F7)F7
PE foam (0.038 W/(m·K))PE foam (0.038 W/(m·K))
PU foam (0.028 W/(m·K))PU foam (0.028 W/(m·K))
PVC casing (0.17 W/(m·K))PVC casing (0.17 W/(m·K))
Pack project…Write one zip file with the project and every file it links (site plan, FMUs, CSV tables, optionally the TRT data files), to pass the project on
Parameter studyParameter study
Parametric study…Vary inputs over a range and size the borehole length (or simulate) at every value (F8)F8
PerspectivePerspective projection: nearer parts look larger.
Potassium formate 29 %Potassium formate 29 %
Previous pagePrevious pageCtrl+PgUp
ProjectProject
RedoRedo
ReferenceReference
Report…Choose the report sections, title block and formats (PDF, HTML, Markdown), preview and write the report; automatic reports after calculationsCtrl+Shift+P
Reset to normalReset to normalCtrl+0
Results summaryResults summaryCtrl+R
Run 3D analysisCompute the current design with the FEM (3D analysis page) and compare it with the analytic design (Shift+F5)Shift+F5
Run…Run the co-simulation (settings on the Settings page).
SaveSave the projectCtrl+S
Save As…Save AsCtrl+Shift+S
SectionsThe borehole sections as thick segments along each borehole.
Show FEM mesh…Preview the mesh the 3D analysis (FEM) would use (the 3D analysis is off on the Project page)
Show demo resultsFill the result pages with synthetic data (no calculation)
Single U 32 × 2.9 mm, borehole Ø 152 mmPE 100 pipes, thermally enhanced grout (λ 2.0 W/(m·K)). Typical values; check them against the product data.
Site planThe site plan on the ground surface, under the boreholes.
Size borehole lengthFind the borehole length that just meets the design limits (F6)F6
SmallSmall
SmallerSmallerCtrl+-
Software OpenGL (slower, works everywhere)Software OpenGL (slower, works everywhere)
SouthView from the south, looking north.
Steel casing (45 W/(m·K))Steel casing (45 W/(m·K))
System (English)System (English)
System (as Windows)System (as Windows)
System OpenGLSystem OpenGL
TRT evaluation with dataTRT evaluation with data
TRT evaluation…Evaluate a thermal response test: import the rig data, check it, estimate λ and R_b* with several methods, and write the values into the project
Text sizeText size
The custom (constant) valuesThe custom (constant) values
The heat pump in the projectThe heat pump in the project
ThemeTheme
Thermally enhanced grout (2.0 W/(m·K))Thermally enhanced grout (2.0 W/(m·K))
Third-party licences…Third-party licences
Time table…Add a source from a CSV time table (first column the time, then one column per output; header "name [unit]").
ToolsTools
TopView from above, north up.
Typical designsTypical designs
Typical fluidsTypical fluids
Undo UnitsUndo Units
Undo history…The list of the changes of the project: click a line to go back to that state
Units…Units in which this project shows values (temperature, length, power, energy, flow)
Unpack project…Unpack a zip written by Pack project into a folder and open the project
Utility corridorUtility corridor
ViewView
WaterWater
Zoom inZoom in (Ctrl+wheel, Ctrl++).
Zoom outZoom out (Ctrl+wheel, Ctrl+−).
as Drilling areaas Drilling area