BoreTherm / Example libraryExample 01 / 23
Worked feature example

Borehole layouts

Compare the available head patterns on the office building reference load. Each saved layout is a separate project, so its coordinates, count and thermal response can be inspected.

16Boreholes
-2.41 °CMinimum mean fluid temperature
16.03 °CMaximum mean fluid temperature
9Variants compared
01 / Project

What the example does

The same office building is placed on nine different borehole patterns: a single borehole, a line, an L-shape, a U-shape, a circle, concentric rings, a hexagonal grid, the 4 × 4 rectangle of the reference design and free coordinates. All variants keep the building loads, the borehole length (150 m) and the design limits. The example shows how the number of boreholes and their arrangement change the fluid temperatures.

Inputs

InputValue
Field16 boreholes, 4 × 4 rectangle, spacing 6.0 × 6.0 m
Boreholeslength 150.0 m, top 4.0 m below the surface, diameter 140 mm
Constructionsingle U, PE pipe 32 × 2.9 mm, shank spacing 70 mm, grout 1.60 W/(m·K)
Groundthermal conductivity 2.60 W/(m·K), heat capacity 2.20 MJ/(m³·K), surface temperature 9.0 °C, geothermal heat flux 0.060 W/m²
Fluid and flow25 % monopropylene glycol, 0.50 l/s per borehole
Loadsmonthly: heating 200 MWh, hot water 8 MWh and cooling 45 MWh per year; peaks 100 kW heating and 45 kW cooling for 6 h
Heat pumpseasonal performance factors 3.8 heating, 2.8 hot water, 5.0 cooling
Design limitsmean fluid temperature between −3.0 °C and 20.0 °C
Period25 years
Variantssingle, line (6), L-shape (7), U-shape (10), circle (8), rectangle 4 × 4 (16), custom (16), concentric rings (19), hexagonal (37)

Run the example in BoreTherm

  1. Start with File → New from example: the office building on a 4 × 4 field.
  2. Open Design → Field layout. Choose a pattern under Layout (type, number of boreholes, spacing) and click Regenerate; for free positions, drag boreholes in the plan or type coordinates in the table.
  3. Press Calculate and read the minimum and maximum mean fluid temperature on Results → Results summary.
  4. Repeat for the other patterns and compare the temperatures with the design limits of −3 °C and 20 °C.
02 / How BoreTherm calculates it

Why the arrangement matters

Each borehole cools its neighbours. BoreTherm calculates this interaction from the positions of all boreholes: the g-function of the field. The same loads then give different temperatures for every layout.

1 Positions and lengthspattern, count, spacing→ coordinates of every head2 Load per metre74 kW peak / total lengthfewer metres → more W/m3 Field g-functionsum of the responses of allboreholes on each other4 Temperaturessuperposition of the monthlyloads and peaks on gCompare TfMin and TfMax with the limits −3 / 20 °C
The calculation behind every variant. Only the positions, and with them the total length, change.
  1. PositionsThe pattern generator turns the pattern, the number of boreholes and the spacing into coordinates. Free positions are entered directly.
  2. Load per metreThe heat pump draws up to 74 kW from the ground in the coldest month. On 16 boreholes of 150 m that is 30.7 W/m; on 6 boreholes it is 81.9 W/m.
  3. Field g-functionFor every pair of boreholes the finite line source gives the temperature that one causes at the other. Their sum over the field, as a function of time, is the g-function. A compact field (hexagonal, rings) has more neighbours per borehole than a line.
  4. TemperaturesThe monthly loads and the 6-hour peaks are superposed on the g-function over 25 years. The result is the mean fluid temperature of every month.
line (6)−16.7 °CL-shape (7)−13.5 °Ccircle (8)−12.5 °CU-shape (10)−7.3 °Crectangle (16)−2.4 °Crings (19)−0.9 °Chexagonal (37)3.5 °Climit −3 °CMinimum mean fluid temperature [°C], 25 years
The lowest mean fluid temperature of each layout. Only the layouts with 16 or more boreholes stay above the limit of −3 °C. The single borehole (not drawn) is far outside at −130 °C: the whole building load on one borehole.
03 / In BoreTherm

The example in BoreTherm

Design → Field layout with the 4 × 4 rectangle of the reference design.
Design → Field layout with the 4 × 4 rectangle of the reference design.
A hexagonal pattern generated on the Field layout page.
A hexagonal pattern generated on the Field layout page.
Free positions: a borehole moved in the plan, with the coordinate table.
Free positions: a borehole moved in the plan, with the coordinate table.
04 / Results

Calculated results

Calculated with BoreTherm for every variant of the example. Displayed values are rounded.

Borehole layouts results plotted from BoreTherm output
Chart of the BoreTherm results in the tables of this section.

Temperatures by variant

VariantBoreholesLength H [m]Tf min [°C]Tf max [°C]Rb* [m K/W]Pump [W]Design limits
circle8150.000-12.46121.6030.11941,516.6limits exceeded
concentric rings19150.000-0.85615.1440.11943,601.9within limits
custom16150.000-2.40516.0360.11943,033.2within limits
rectangle 4 × 4 (reference)16150.000-2.41316.0260.11943,033.2within limits
hexagonal37150.0003.54312.9030.11947,014.3within limits
line6150.000-16.72225.9810.11941,137.4limits exceeded
L-shape7150.000-13.50023.7250.11941,327.0limits exceeded
single borehole1150.000-129.862106.3780.1194189.6limits exceeded
U-shape10150.000-7.25719.7790.11941,895.7limits exceeded
05 / Discussion

What the example shows

All layouts carry the same building load. A layout with fewer boreholes therefore has fewer metres and a higher load per metre, which is the main reason for the large differences. Compare layouts together with their total length: these variants show the geometry, they are not equally sized designs. To compare layouts at equal performance, size each one (Size borehole length) or let Optimize search the plot.

At equal total length, a compact layout is warmer in winter than a line only in the long run: in the first years the boreholes hardly see each other, after decades the neighbours' cooling adds up. The g-function contains this growth.