Parametric studies

Run the stored one-at-a-time office study and a nine-point grid of conductivity and heating energy. Export each run for comparison.

16Boreholes
-2.41 °CMinimum mean fluid temperature
16.03 °CMaximum mean fluid temperature
1Variants compared
01 / Project

What the example does

How much longer must the office boreholes be if the ground conducts less heat, or the building needs more? A parametric study runs the sizing for a grid of nine combinations: ground conductivity 2.0, 2.6 and 3.2 W/(m·K) times heating demand 0.8, 1.0 and 1.2 of the reference.

Inputs

InputValue
Field16 boreholes, 4 × 4 rectangle, spacing 6.0 × 6.0 m
Boreholeslength 150.0 m, top 4.0 m below the surface, diameter 140 mm
Constructionsingle U, PE pipe 32 × 2.9 mm, shank spacing 70 mm, grout 1.60 W/(m·K)
Groundthermal conductivity 2.60 W/(m·K), heat capacity 2.20 MJ/(m³·K), surface temperature 9.0 °C, geothermal heat flux 0.060 W/m²
Fluid and flow25 % monopropylene glycol, 0.50 l/s per borehole
Loadsmonthly: heating 200 MWh, hot water 8 MWh and cooling 45 MWh per year; peaks 100 kW heating and 45 kW cooling for 6 h
Heat pumpseasonal performance factors 3.8 heating, 2.8 hot water, 5.0 cooling
Design limitsmean fluid temperature between −3.0 °C and 20.0 °C
Period25 years
Studygrid: ground conductivity 2.0 / 2.6 / 3.2 W/(m·K) × heating demand 0.8 / 1.0 / 1.2; each run sized

Run the example in BoreTherm

  1. Press Parametric study. Choose the parameters, their values and the kind of study (one at a time, or a full grid), and whether each run is simulated or sized.
  2. Run the study.
  3. Advanced analysis → Studies & uncertainty → Parametric study shows the lines, the heat map, the tornado chart and the table of all runs.
  4. A run can be applied to the project from the table.
02 / How BoreTherm calculates it

How a study runs

1 Axesλ: 2.0, 2.6, 3.2 W/(m·K)heating × 0.8, 1.0, 1.22 Runsgrid: 3 × 3 = 9 projects,each a copy with its values3 Size eachrequired H for the limits(as Size borehole length)4 CollectH, total length, TfMinper run5 Chartslines per axis, heat map,tornado (one at a time)H from 112 m (λ 3.2, × 0.8) to 184 m (λ 2.0, × 1.2)
The grid of the example. Every run is an ordinary sizing with changed inputs.
  1. AxesEach parameter is varied over the listed values, in display units.
  2. RunsThe grid combines every value of one axis with every value of the other.
  3. Size eachEvery run finds its own required length.
  4. CollectThe results are kept per run, with the values that produced them.
  5. ChartsLines and the heat map show the grid; a one-at-a-time study gives the tornado chart.
03 / In BoreTherm

The example in BoreTherm

The Parametric study dialog: two axes in a full grid.
The Parametric study dialog: two axes in a full grid.
The result: required length against conductivity for each heating demand.
The result: required length against conductivity for each heating demand.
A one-at-a-time study: the tornado chart of the stored office study.
A one-at-a-time study: the tornado chart of the stored office study.
04 / Results

Calculated results

Calculated with BoreTherm for every variant of the example. Displayed values are rounded.

λ [W/(m K)]Heating multiplierH [m]Total [m]Tf min [°C]
2.0000.800136.8512,189.622-2.993
2.0001.000160.5392,568.619-2.995
2.0001.200183.7612,940.183-2.999
2.6000.800123.0011,968.010-2.998
2.6001.000143.7182,299.484-2.998
2.6001.200164.4182,630.694-2.998
3.2000.800112.4351,798.960-2.998
3.2001.000130.5942,089.496-2.998
3.2001.200148.9982,383.975-2.998
Parametric studies results plotted from BoreTherm output
Chart of the BoreTherm results in the tables of this section.

Temperatures by variant

VariantBoreholesLength H [m]Tf min [°C]Tf max [°C]Rb* [m K/W]Pump [W]Design limits
office reference16150.000-2.41316.0260.11943,033.2within limits
05 / Discussion

What the example shows

At the reference demand the length falls from 161 m to 131 m as the conductivity rises from 2.0 to 3.2 W/(m·K). A 20 % change in heating demand changes the length by about 14 %. Cooling, hot water, geometry and limits stay at their saved values in every run.

The grid is a deterministic sensitivity study: it says how the result responds, not how likely each value is. For that, see the Monte Carlo example.