Generates one year of seasonal operation of a borehole thermal energy store, repeated every year. Choose Charge, Rest or Discharge for each calendar month and whether the series prescribes the inlet temperature or the ground load; enter for charging and for discharging the inlet temperature or load, the flow (whole field or per borehole; volume or mass flow) and the daily operating hours, and the row step. Charging runs the connections as drawn (direction +1), discharging reverses them (direction −1); the pump is off at rest and outside the daily hours. Review the preview (months, operating hours and, with a prescribed load, the energy per year) before Generate: the series replaces the project's time-series loads. Use in the dynamic model also switches the borehole model to Dynamic with inlet, flow and flow direction from the series. The flow-direction rule itself (fixed, from the time series, automatic with a reversal hysteresis and a minimum time between reversals) is set on Design limits & simulation. The storage results count all charged and discharged heat; there is no return-temperature cut-off.

Step-by-step workflows · Menus and keyboard

BTES operation in BoreTherm
English GUI; click to enlarge.
Controls captured from the BoreTherm GUI. Ranges are interface bounds; example values depend on the open project.
ControlMeaning / actionUnitRange / choicesExample value
JanuaryCharge, rest or discharge in this calendar month of the generated annual schedule.Charge / Rest / Discharge
FebruaryCharge, rest or discharge in this calendar month of the generated annual schedule.Charge / Rest / Discharge
MarchCharge, rest or discharge in this calendar month of the generated annual schedule.Charge / Rest / Discharge
AprilCharge, rest or discharge in this calendar month of the generated annual schedule.Charge / Rest / Discharge
MayCharge, rest or discharge in this calendar month of the generated annual schedule.Charge / Rest / Discharge
JuneCharge, rest or discharge in this calendar month of the generated annual schedule.Charge / Rest / Discharge
JulyCharge, rest or discharge in this calendar month of the generated annual schedule.Charge / Rest / Discharge
AugustCharge, rest or discharge in this calendar month of the generated annual schedule.Charge / Rest / Discharge
SeptemberCharge, rest or discharge in this calendar month of the generated annual schedule.Charge / Rest / Discharge
OctoberCharge, rest or discharge in this calendar month of the generated annual schedule.Charge / Rest / Discharge
NovemberCharge, rest or discharge in this calendar month of the generated annual schedule.Charge / Rest / Discharge
DecemberCharge, rest or discharge in this calendar month of the generated annual schedule.Charge / Rest / Discharge
Prescribe:What the series prescribes: the inlet temperature of the fluid (the dynamic model computes the heat rate), or the heat rate into the ground.Inlet temperature / Ground load
Flow unit:Unit of the flows below. A mass flow is stored as it is and converted with the density at the inlet temperature of each step.l/s / m³/h / l/min / m³/s / kg/s (mass flow) / kg/h (mass flow) / t/h (mass flow)
Flow refers to:The flows are the pump's flow (whole field) or the mean flow through one borehole.Whole field / Per borehole
Step:Step between two rows of the series (the dynamic model's control step must fit it).5 min / 10 min / 15 min / 20 min / 30 min / 60 min
Use in the dynamic modelSwitches the borehole model to Dynamic and sets its inlet, flow and flow direction to follow the time series. Off: only the loads are replaced.
Btes charge tinInlet temperature while charging.°C-30 to 15070
Btes charge loadHeat rate injected into the ground while charging.kW0 to 1e+06100
Btes charge flowFlow in the unit chosen above.l/s0 to 1e+060.5
Btes charge fromStart of the daily operation (0 - 24 = all day).h0 to 240
Btes charge toEnd of the daily operation (an end before the start runs over midnight).h0 to 2424
Btes discharge tinInlet temperature while discharging.°C-30 to 15030
Btes discharge loadHeat rate extracted from the ground while discharging.kW0 to 1e+06100
Btes discharge flowFlow in the unit chosen above.l/s0 to 1e+060.5
Btes discharge fromStart of the daily operation (0 - 24 = all day).h0 to 240
Btes discharge toEnd of the daily operation (an end before the start runs over midnight).h0 to 2424
Reset viewShow all data (also: double-click the plot).
Chart style buttonChart style: title, axis titles, legend, colours, line widths and markers, fonts, grid and background (also in the chart's context menu).
PNG…Export the plot as a PNG image.
SVG…Export the plot as a vector SVG image (for Word, Inkscape, …).
PDF…Export the plot as a vector PDF.
CSV…Export the plotted data as CSV.
GenerateGenerate the configured output. In BTES this creates the operation series; in Report it writes the selected report files.
CancelClose without accepting unapplied edits.
Btes charge tinInlet temperature while charging.°F-22 to 302158
Btes charge loadHeat rate injected into the ground while charging.MW0 to 10000.1
Btes discharge tinInlet temperature while discharging.°F-22 to 30286
Btes discharge loadHeat rate extracted from the ground while discharging.MW0 to 10000.1