Ground
Choose homogeneous or layered ground. Conductivity controls heat spreading; volumetric heat capacity controls diffusion time. Surface temperature and geothermal heat flux define the undisturbed depth temperature. The last layer extends to infinity below; its thickness is not used. Groundwater speed and direction affect the response; the speed is the Darcy velocity (specific discharge), not the pore velocity. A strong-flow near-field result needs an independent accuracy check.
Step-by-step workflows · Menus and keyboard

| Control | Meaning / action | Unit | Range / choices | Example value |
|---|---|---|---|---|
| Ground model: | Homogeneous ground (one λ and C), or a table of horizontal layers. | Homogeneous / Layered – effective properties / Layered – segmented | ||
| Undisturbed temperature: | How the undisturbed ground temperature Tm of the borehole is evaluated. | Mid-depth / Active-length average | ||
| Typical values: | Fill conductivity and heat capacity with typical values (VDI 4640). Use measured values (thermal response test) whenever available. | — choose typical values — / Clay / silt, dry (λ = 0.5, C = 1.6) / Clay / silt, water saturated (λ = 1.7, C = 2.4) / Sand, dry (λ = 0.4, C = 1.4) / Sand, water saturated (λ = 2.4, C = 2.5) / Gravel, water saturated (λ = 1.8, C = 2.4) / Claystone / siltstone (λ = 2.2, C = 2.3) / Sandstone (λ = 2.3, C = 2.2) / Limestone (λ = 2.8, C = 2.2) / Granite (λ = 3.4, C = 2.4) / Gneiss (λ = 2.9, C = 2.2) / Basalt (λ = 1.7, C = 2.6) / Quartzite (λ = 6.0, C = 2.1) | ||
| Thermal conductivity λ: | Thermal conductivity λ of the ground, averaged over the borehole depth. Typical 1.5 – 4 W/(m·K); measured by a thermal response test (TRT). | W/(m·K) | 0.1 to 10 | 2.6 |
| Volumetric heat capacity C: | Volumetric heat capacity ρ·c of the ground. Typical 1.8 – 2.8 MJ/(m³·K). | MJ/(m³·K) | 0.5 to 5 | 2.2 |
| Surface temperature: | Annual mean ground surface temperature. Approximately the mean annual air temperature plus 1 – 2 K. | °C | -20 to 40 | 9 |
| Geothermal input: | Enter the geothermal heat flux q or the geothermal gradient G; the other value is shown read-only, converted with q = λ·G. The project stores the heat flux. | Geothermal heat flux / Geothermal gradient | ||
| Geothermal heat flux: | Geothermal heat flux from the interior. Typical 0.04 – 0.10 W/m² (Europe ≈ 0.065). | W/m² | 0 to 1 | 0.06 |
| Geothermal gradient: | Geothermal gradient G: increase of the undisturbed ground temperature with depth. Typical 2.5 – 3.5 K/100 m. Converted with q = λ·G; in layered ground λ is chosen so that the undisturbed temperature Tm stays the same. | K/100 m | 0 to 20 | 2.31 |
| Add | Insert a new layer below the selected one (λ and C from the homogeneous values). | |||
| Remove | Remove the selected evaluation item or interval from this table. | |||
| Move up | Move the selected layer earlier in the layer table; recalculate its depth placement. | |||
| Move down | Move the selected layer later in the layer table; recalculate its depth placement. | |||
| Typical values → selected layer: | Fill λ and C of the selected layer with typical values (VDI 4640); a layer with a generic name is renamed after the rock type. | — choose — / Clay / silt, dry (λ = 0.5, C = 1.6) / Clay / silt, water saturated (λ = 1.7, C = 2.4) / Sand, dry (λ = 0.4, C = 1.4) / Sand, water saturated (λ = 2.4, C = 2.5) / Gravel, water saturated (λ = 1.8, C = 2.4) / Claystone / siltstone (λ = 2.2, C = 2.3) / Sandstone (λ = 2.3, C = 2.2) / Limestone (λ = 2.8, C = 2.2) / Granite (λ = 3.4, C = 2.4) / Gneiss (λ = 2.9, C = 2.2) / Basalt (λ = 1.7, C = 2.6) / Quartzite (λ = 6.0, C = 2.1) | ||
| Uniform aquifer over the whole depth | Groundwater flows horizontally through the whole ground with one Darcy velocity. The heat it carries away is modelled with the moving finite line source (Molina-Giraldo et al. 2011). For an aquifer in some layers only, enter the velocities in the layer table instead. | |||
| Darcy velocity u: | Darcy velocity (specific discharge) u of the groundwater, in metres per year. 1 m/yr = 3.17·10⁻⁸ m/s. Typical: clay < 0.1, silt/fine sand 0.1 – 10, sand and gravel 10 – 1000 m/yr (from hydraulic conductivity × gradient). | m/yr | 0 to 10000 | 0 |
| Flow direction: | Direction the groundwater flows towards, in degrees from the +x axis of the field, counter-clockwise (0° = +x, 90° = +y). | ° | 0 to 359.9 | 0 |
| Water heat capacity: | Volumetric heat capacity (ρc)w of the groundwater; 4.18 MJ/(m³·K) for water at about 10 °C. | MJ/(m³·K) | 3 to 4.3 | 4.18 |
| Surface temperature: | Annual mean ground surface temperature. Approximately the mean annual air temperature plus 1 – 2 K. | °F | -4 to 104 | 48.2 |