Ground

Choose homogeneous or layered ground. Conductivity controls heat spreading; volumetric heat capacity controls diffusion time. Surface temperature and geothermal heat flux define the undisturbed depth temperature. The last layer extends to infinity below; its thickness is not used. Groundwater speed and direction affect the response; the speed is the Darcy velocity (specific discharge), not the pore velocity. A strong-flow near-field result needs an independent accuracy check.

Step-by-step workflows · Menus and keyboard

Ground in BoreTherm
English GUI; click to enlarge.
Controls captured from the BoreTherm GUI. Ranges are interface bounds; example values depend on the open project.
ControlMeaning / actionUnitRange / choicesExample value
Ground model:Homogeneous ground (one λ and C), or a table of horizontal layers.Homogeneous / Layered – effective properties / Layered – segmented
Undisturbed temperature:How the undisturbed ground temperature Tm of the borehole is evaluated.Mid-depth / Active-length average
Typical values:Fill conductivity and heat capacity with typical values (VDI 4640). Use measured values (thermal response test) whenever available.— choose typical values — / Clay / silt, dry (λ = 0.5, C = 1.6) / Clay / silt, water saturated (λ = 1.7, C = 2.4) / Sand, dry (λ = 0.4, C = 1.4) / Sand, water saturated (λ = 2.4, C = 2.5) / Gravel, water saturated (λ = 1.8, C = 2.4) / Claystone / siltstone (λ = 2.2, C = 2.3) / Sandstone (λ = 2.3, C = 2.2) / Limestone (λ = 2.8, C = 2.2) / Granite (λ = 3.4, C = 2.4) / Gneiss (λ = 2.9, C = 2.2) / Basalt (λ = 1.7, C = 2.6) / Quartzite (λ = 6.0, C = 2.1)
Thermal conductivity λ:Thermal conductivity λ of the ground, averaged over the borehole depth. Typical 1.5 – 4 W/(m·K); measured by a thermal response test (TRT).W/(m·K)0.1 to 102.6
Volumetric heat capacity C:Volumetric heat capacity ρ·c of the ground. Typical 1.8 – 2.8 MJ/(m³·K).MJ/(m³·K)0.5 to 52.2
Surface temperature:Annual mean ground surface temperature. Approximately the mean annual air temperature plus 1 – 2 K.°C-20 to 409
Geothermal input:Enter the geothermal heat flux q or the geothermal gradient G; the other value is shown read-only, converted with q = λ·G. The project stores the heat flux.Geothermal heat flux / Geothermal gradient
Geothermal heat flux:Geothermal heat flux from the interior. Typical 0.04 – 0.10 W/m² (Europe ≈ 0.065).W/m²0 to 10.06
Geothermal gradient:Geothermal gradient G: increase of the undisturbed ground temperature with depth. Typical 2.5 – 3.5 K/100 m. Converted with q = λ·G; in layered ground λ is chosen so that the undisturbed temperature Tm stays the same.K/100 m0 to 202.31
AddInsert a new layer below the selected one (λ and C from the homogeneous values).
RemoveRemove the selected evaluation item or interval from this table.
Move upMove the selected layer earlier in the layer table; recalculate its depth placement.
Move downMove the selected layer later in the layer table; recalculate its depth placement.
Typical values → selected layer:Fill λ and C of the selected layer with typical values (VDI 4640); a layer with a generic name is renamed after the rock type.— choose — / Clay / silt, dry (λ = 0.5, C = 1.6) / Clay / silt, water saturated (λ = 1.7, C = 2.4) / Sand, dry (λ = 0.4, C = 1.4) / Sand, water saturated (λ = 2.4, C = 2.5) / Gravel, water saturated (λ = 1.8, C = 2.4) / Claystone / siltstone (λ = 2.2, C = 2.3) / Sandstone (λ = 2.3, C = 2.2) / Limestone (λ = 2.8, C = 2.2) / Granite (λ = 3.4, C = 2.4) / Gneiss (λ = 2.9, C = 2.2) / Basalt (λ = 1.7, C = 2.6) / Quartzite (λ = 6.0, C = 2.1)
Uniform aquifer over the whole depthGroundwater flows horizontally through the whole ground with one Darcy velocity. The heat it carries away is modelled with the moving finite line source (Molina-Giraldo et al. 2011). For an aquifer in some layers only, enter the velocities in the layer table instead.
Darcy velocity u:Darcy velocity (specific discharge) u of the groundwater, in metres per year. 1 m/yr = 3.17·10⁻⁸ m/s. Typical: clay < 0.1, silt/fine sand 0.1 – 10, sand and gravel 10 – 1000 m/yr (from hydraulic conductivity × gradient).m/yr0 to 100000
Flow direction:Direction the groundwater flows towards, in degrees from the +x axis of the field, counter-clockwise (0° = +x, 90° = +y).°0 to 359.90
Water heat capacity:Volumetric heat capacity (ρc)w of the groundwater; 4.18 MJ/(m³·K) for water at about 10 °C.MJ/(m³·K)3 to 4.34.18
Surface temperature:Annual mean ground surface temperature. Approximately the mean annual air temperature plus 1 – 2 K.°F-4 to 10448.2