HomeFeaturesExamplesTutorialsHelpTheoryVerificationPricingContact
BoreTherm Online help

Thermal plume

Choose analytic or available 3D results, time, depth, extent and resolution. Threshold contours refer to change from undisturbed temperature. Layered and groundwater responses depend on the selected model. A plume is a screening prediction; verify sensitive near-field decisions with mesh/domain convergence.

Step-by-step workflows · Menus and keyboard

Thermal plume in BoreTherm
English GUI; click to enlarge.
Controls captured from the BoreTherm GUI. Ranges are interface bounds; example values depend on the open project.
ControlMeaning / actionUnitRange / choicesExample value
Source:2D: the analytic plume of the design (after Calculate, F5). 3D: the temperature field of the 3D analysis (Run 3D analysis). Overlaid: 2D solid, 3D dashed.2D (analytic) / 3D (FEM) / 2D and 3D overlaid
Time:Select one of the listed alternatives.End of the period / Worst moment (largest extent) / A month
Plume monthMonth of operation (1 = the first month); the map shows its end.1 to 300300
Depth:Select one of the listed alternatives.Averaged over the active borehole length / At a depth
Plume depthDepth of the plan view below the surface.m0.5 to 200079
Thresholds [K]:Temperature-change thresholds in K, separated by ';' (negative: cooling, positive: warming). Default ±3 K. BoreTherm has no built-in legal limits.
Dimension linesEnables or disables this option.
The site plan's boundaries (property lines)Enables or disables this option.
Add lineAdd an evaluation line; configure its coordinates and sample spacing.
Add pointAdd an evaluation point; configure its position and inspect the calculated value.
RemoveRemove the selected evaluation item or interval from this table.
Export image…Save the current view as an image with its current display settings.
Export CSV…Write the displayed numerical table to a CSV file using the selected CSV format.
Plume monthMonth of operation (1 = the first month); the map shows its end.1 to 1212
Plume monthMonth of operation (1 = the first month); the map shows its end.1 to 3636
Plume depthDepth of the plan view below the surface.ft1.6 to 6561.7850.3
Thresholds [°F]:Temperature-change thresholds in °F, separated by ';' (negative: cooling, positive: warming). Default ±3 K. BoreTherm has no built-in legal limits.