HomeFeaturesExamplesTutorialsHelpTheoryVerificationPricingContact
BoreTherm Online help

Time series import

Map source columns, time units, temperature/power/flow units and sign conventions. Inspect the preview, timestamp coverage and interpolation before applying. Short coverage or invalid timestamps must be addressed before design use.

Step-by-step workflows · Menus and keyboard

Time series import in BoreTherm
English GUI; click to enlarge.
Controls captured from the BoreTherm GUI. Ranges are interface bounds; example values depend on the open project.
ControlMeaning / actionUnitRange / choicesExample value
Time series fileLocal file/folder selected in this example.
Browse…Choose a local file or folder.
Time:Unit of the time column (time since the start of operation; only the step matters).seconds / minutes / hours / days
Ignore the time column, rows everyFor files whose time column is a row number or a date: the rows follow each other at this constant step.
Step between two rows.Step between two rows.min0.1 to 144060
Ground load:Select one of the listed alternatives.W / kW
Sign:Sign convention of the load column. BoreTherm stores ground loads with > 0 = injection.> 0: heat injected into the ground (cooling) / > 0: heat extracted from the ground (heating)
Flow:Unit of the flow column (0 = pump off). A mass flow is stored as it is and converted to a volume flow with the density of the fluid at the inlet temperature of each step.m³/s / l/s / m³/h / l/min / kg/s (mass flow) / kg/h (mass flow) / t/h (mass flow)
Flow refers to:Whole field: the flow of the pump. Per borehole: the mean flow through one borehole; the field's flow follows from the borehole connections (boreholes in series carry the same flow one after the other).Whole field / Per borehole
Direction column:Optional column with the flow direction: +1 normal (the connections as drawn: charging), −1 reversed (discharging), 0 keep the previous direction.Automatic (a column named "direction") / None / Column 1 / Column 2 / Column 3
Use the dynamic borehole model with this series (flow, direction and inlet temperature from the file)Switches the borehole model to Dynamic (Design limits simulation) and lets it take the inlet temperature, the flow and the flow direction from the columns of the series. The steady and short-time models use the hour means of the load and the project's nominal flow.
ImportImport the mapped time series after checking units, signs and coverage.
CancelClose without accepting unapplied edits.