BoreTherm Online help

TRT test setup

Describe borehole geometry, construction, fluid, flow and heat input, ground heat capacity and undisturbed temperature. Match the measured test conditions and record their provenance. Fitting inputs and uncertainty estimates depend on these assumptions.

Step-by-step workflows · Menus and keyboard

TRT test setup in BoreTherm
English GUI; click to enlarge.
Controls captured from the BoreTherm GUI. Ranges are interface bounds; example values depend on the open project.
ControlMeaning / actionUnitRange / choicesExample value
Copy borehole, pipes, fluid and ground from the projectCopy the design construction and material settings into this TRT setup; confirm they describe the measured test.
Length H:Active length of the test boreholem1 to 3000150
Buried depth D:Depth of the top of the active lengthm0 to 5004
Borehole diameter:Borehole diameter (2 rb)mm50 to 600140
Time since grouting:Days between grouting and the start of the test (quality check)days-1 to 3650-1
Pipe type:Select one of the listed alternatives.Single-U / Double-U / Triple-U / Coaxial / Multi-U (4–8) / Helix (spiral coil)
Pipe outer diameter:Outer diameter of the pipes (coaxial: outer pipe)mm10 to 20032
Pipe wall thickness:Wall thickness of the pipesmm0.5 to 202.9
Shank spacing:Centre-to-centre distance of opposite legsmm0 to 30070
Grout conductivity:Thermal conductivity of the groutW/(m·K)0.1 to 101.6
Pipe conductivity:Thermal conductivity of the pipe wallW/(m·K)0.05 to 600.42
Fluid:Select one of the listed alternatives.Water / / Glycols / Monoethylene glycol (MEG) / Monopropylene glycol (MPG) / / Alcohols / Ethanol / Methanol / / Salt solutions / Potassium formate / Potassium acetate / Potassium carbonate / Calcium chloride / Sodium chloride / / Glycerol / / Custom (constant properties) / Table (temperature-dependent)
Mass fraction:Mass fraction of the antifreeze%0 to 6025
Heat capacity C:Volumetric heat capacity of the ground: fixed in the evaluation unless it is estimatedMJ/(m³·K)0.5 to 52.2
Surface temperature:Mean ground surface temperature (T0 plausibility check)°C-20.1 to 409
Geothermal heat flux:Geothermal heat flux (T0 plausibility check)W/m²-0.005 to 0.30.06
Method:Select one of the listed alternatives.Initial circulation (before the heating) / Manual value / Depth profile (mean over the active length)
Averaging window:Averaging window before the heating startmin1 to 144020
T0 (manual):Undisturbed ground temperature°C-10.1 to 100-10.1
Add depthAdd a depth-resolved TRT input row.
Remove depthRemove the selected depth-resolved input row.
Power:Q = ρ cp V̇ (Tin − Tout) with the fluid properties at the mean fluid temperature, or the heater / heat meter columnMeasured (power column) / From flow and ΔT (inlet − outlet)
Heating start:Start of the heating in the time of the datah-1000 to 100001
Heating end:End of the heating since its start; the recovery follows (automatic: the last sample with heating power)h-0.1 to 10000-0.1