The one idea: the borehole itself stores heat
BoreTherm checks the mean fluid temperature Tf, the mean of the inlet and outlet temperature of the fluid, against the design limits. The steady model treats the inside of the borehole as one resistance, the effective borehole thermal resistance Rb*: the fluid, the pipes and the grout store nothing, so a load step reaches the fluid temperature in full at once. The dynamic model replaces that resistance by a network on depth levels: the fluid flows down and up the pipes, takes time to pass, and the grout stores heat. The ground outside the wall stays the same analytic g-function, the dimensionless temperature response of the field to a constant heat rate.
Tf = Tb + q · Rb*Tw = Tm + [Hhist + g(h) q̄w] / (2πλ)Tf = (Tin + Tout) / 2q is the heat rate per metre of borehole (positive into the ground), Tb and Tw the borehole wall temperature, Tm the undisturbed ground temperature, λ the thermal conductivity of the ground and Hhist the effect of the earlier wall fluxes; ṁcp is the capacity flow (mass flow × specific heat) and Q the heat rate. q̄w is the heat flux through the wall, taken from the grout nodes. It differs from the fluid load while the borehole stores or releases heat. Once a load has been steady for a few days the two agree, and the dynamic model gives the steady result.
The workflow
Hourly loads are the first step: they put the daily cycle into the design. The borehole model is the second: it decides what happens inside the borehole within those hours. Both commands of the Calculation menu use the chosen model: Calculation › Calculate at the given length, Size borehole length to find the required length. Besides the steady and the dynamic model there is Short-time capacity: the steady model plus the heat capacity of fluid, pipes and grout at short times, as one combined response.
Verify with dynamic model (Required borehole length page) copies the project, sets the boreholes to the sized (mean) length, switches the borehole model to Dynamic with the project’s dynamic settings, and runs it, together with the steady model at the same length for comparison. It changes nothing in the project. The result block shows the hour-mean range against the limits, the range at the output interval, and the steady range.
How the dynamic model works
- Depth levels of Δz (default 2 m), each with the resistance–capacity network of Bauer et al. (TRCM): one grout node per leg, resistances fluid–grout (Rfg), grout–wall (Rgb) and grout–grout (Rgg), derived from the matrix of the multipole method (an analytical solution for the pipes in the grout) so that the steady state reproduces the borehole resistance Rb and the internal resistance Ra between the legs exactly.
- Plug flow. The fluid is cut into cells of equal volume that move with the flow (Lagrangian). A temperature front keeps its shape and arrives after the transit time, the time the fluid needs to pass through the borehole; there is no numerical diffusion.
- Heat exchange. Each cell exchanges heat with the grout nodes of the levels it passes, with an exponentially fitted, time-centred step that is exact for constant node temperatures.
- Ground. One wall temperature, uniform along the depth and equal in all boreholes (as the g-function with a uniform borehole wall temperature, UBWT, here with the cylindrical-source correction); the history is kept by the load aggregation of Claesson and Javed, which lumps older wall fluxes into longer blocks. Node temperatures are affine in Tin and Tw, so both are solved exactly, without iterating.
- Outside the dynamic periods (option: first and last year, custom periods) the steady model runs on the same grid, so the ground history stays continuous.
The theory with the example
Hourly loads: the daily cycle is in the design
The generator keeps every month’s energy and its peak power, and spreads the rest by the outdoor temperature and the use pattern (here: office hours on working days). The office then draws its peak for a whole working day, day after day, while the monthly model assumes 6 hours at the end of a month at mean load. With the same field the lowest hourly Tf is −3.06 °C against −2.41 °C monthly.
The borehole interior: the first hours of a load step
How each result is derived
| Result | How BoreTherm derives it | Example at 150.7 m |
|---|---|---|
| Hourly ground load Q | hourly building loads × the SPF factors of Heat pump › Setup (SPF: seasonal performance factor of the heat pump); one year, repeated | 75.3 kW from the ground in the block: heating 100 kW × 0.737 + DHW |
| Steady Tf (hourly) | Tm + Σ Δq g / (2πλ) + q Rb*, FFT convolution of the hourly steps | first hour of the block −1.68 °C, lowest −3.00 °C |
| Dynamic Tf | (Tin + Tout)/2 per control step, averaged over the hour | first hour −0.87 °C, lowest −2.89 °C |
| Inlet / outlet | steady: Tf ± Q/(2ṁcp); dynamic: the fluid entering and leaving the field | lowest inlet −4.18 (steady) / −4.09 °C (dynamic) |
| Depth levels and steps | K = round(H/Δz) levels; sub-step = transit time / 10 | 75 levels of 2.01 m, step 300 s, sub-step 32.5 s |
| Energy balance | largest step error |load − wall − storage| over the gross flows (T-P11b-4) | 1.7·10⁻¹⁴; 25 years: 2463 MWh taken by the fluid, 2463 MWh through the walls |
| Monthly view | base = the last hour of the month; peaks = the extremes of its 730 hours | the Mean fluid temperature and Annual pages work unchanged |
| Limits check, sizing | hour means of all years (or the last year) against Tf,min, Tf,max | −2.89 … 16.00 °C: limits met |
Hourly loads: office pattern, 200 MWh heating (peak 100 kW), 45 MWh cooling, 8 MWh DHW, as the monthly table.
The example in numbers
| Loads and run | Borehole model | Tf,min [°C] | Length |
|---|---|---|---|
| Monthly loads, 150 m (the project) | steady, monthly | −2.41 | — |
| Monthly loads, Size borehole length | steady, monthly | −3.00 | 143.7 m |
| Hourly loads, 150 m | steady, hourly | −3.06 | — |
| Hourly loads, Size borehole length | steady, hourly | −3.00 | 150.7 m |
| Verify at 150.7 m | short-time capacity | −2.92 | — |
| Verify at 150.7 m | dynamic | −2.89 | meets the limits |
| Hourly loads, Size borehole length | dynamic | −3.00 | 149.5 m |
The limits are −3 / 20 °C. Hourly loads make the field 7.0 m per borehole longer than the monthly sizing (112 m in total for the 16 boreholes): the working-day blocks are colder than the monthly peak. The dynamic model at the hourly length keeps Tf,min 0.11 K above the limit, so the steady length is confirmed with a small reserve. Size borehole length with the dynamic model gives 149.5 m, 1.2 m shorter: 10 dynamic runs of 25 years each, minutes instead of seconds for a saving of 0.8 %.
Limits to keep in mind
- The dynamic model needs hourly or time-series loads; with monthly loads Verify says so. Generated hourly loads are synthetic: they keep the monthly energies and peaks, not the real weather.
- The limits are checked on hour means. With steps shorter than an hour the series at the output interval can be more extreme; the verification shows both.
- Version 1 of the ground coupling: one wall temperature, uniform along the depth and equal in all boreholes (options per ring or per borehole exist for thermal stores).
- Run time grows with the period and the transit time, not with the control step: a 25-year run takes a minute or more, and sizing with the dynamic model runs it at every trial length. The first-and-last-year option is much faster.
- Pump on/off by load: loads asked for while the pump is off are not delivered; the results report that energy.
- The fluid properties are constant unless Temperature-dependent fluid properties is on (laminar flow in cold periods).
Numbers calculated with BoreTherm. Hourly loads generated with the office pattern. Theory: BoreTherm theory manual.