The one idea: a short, fat borehole that also carries the building
An energy pile is a cast-in-place concrete pile with the pipes tied to its reinforcement cage. Thermally it is a short, wide borehole whose filling is structural concrete. Two things set it apart: the concrete stores much more heat than borehole grout, and the pipes lie near the perimeter with a concrete core inside them. Mechanically the pile carries the building: a temperature change makes it shorten or lengthen, or, where it cannot move, builds up stress.
Tp = Tf − q Rb*/2ΔTp = Tp − Tmε = αc ΔTp, ΔL = ε Hσ = Ec αc ΔTpTf is the mean fluid temperature (the mean of inlet and outlet), the temperature BoreTherm checks against the design limits; Rb* is the effective thermal resistance between the fluid and the pile wall. q is the ground load per metre (> 0 into the ground), so in heating the pile is a little warmer than the fluid. Tm is the undisturbed ground temperature, αc the thermal expansion coefficient and Ec the elastic modulus of the concrete, ε the strain and ΔL the length change of a pile of length H. A negative ΔTp (heating mode) shortens a free pile and puts a restrained pile in tension; a positive one (cooling) lengthens it or compresses it.
The workflow
The pile geometry comes from the structural design. The energy design checks what the piles can deliver and what temperature change they see. The ground side is the g-function, the dimensionless temperature response of the piles to a constant heat rate; its boundary condition at the pile wall is either a uniform heat flux (UHTR) or a uniform wall temperature (UBWT).
- Pile geometry. Borehole diameter = pile diameter. Shank spacing = diameter of the circle through the pipe centres (cage diameter minus bars and cover). Grout values = concrete values. The design library has piles of Ø 600 mm (double U, helix) and Ø 1200 mm (4 U-tubes).
- U-loops. In parallel (manifold at the pile head) or in series (one pipe around the cage). In series every leg carries the whole flow: lower pipe resistance, much higher pressure drop.
- Borehole model. Short-time capacity: the steady model plus the heat capacity of fluid, pipes and grout at short times. Only this model uses the ring model of the pile; the steady model treats the concrete as a resistance without storage, and the results warn about it.
- Pile inlet range. Lowest and highest field inlet temperature Tin for the pile, default 0 °C and 40 °C. They give warnings, not sizing criteria.
How the calculation works
- Pile resistance. Rb and Rb* from the multipole method (an analytical solution for the pipes in the grout) with the concrete as grout. Loops in series get Rb* of the whole circuit.
- g-function. The finite line source at the pile radius with a uniform heat flux (UHTR), as in the pile literature, plus the cylindrical short-time correction. With the pile head at the surface the uniform wall temperature is not conservative.
- Ring model. A radial model of core, pipe ring and cover (next section). It changes only the short-time response; its long-time end is the steady model.
- Simulation. As for a borefield: monthly base and peak loads, or hourly. Tf and the inlet and outlet temperatures.
- Pile temperature from the sustained values: the monthly base in monthly mode (short peaks do not reach the pile as a whole), every hour in the hourly and time-series modes.
- Screening: the smallest and largest ΔTp of the whole period, then strain, length change and stress.
- Pile inlet check: the lowest and highest field inlet temperature (the coldest and warmest fluid at the concrete) against the pile range.
The theory
The ring model: where the concrete stores heat
The equivalent single pipe of a borehole puts all pipes on the axis and all grout outside them. For a pile that is the wrong geometry: a large part of the concrete is the core inside the pipe ring. The ring model resolves it (16 core cells, 8 cover cells, 90 ground cells, second-order backward-difference (BDF2) time steps).
The capacity effect of a pile decays slowly, roughly as 1/t. BoreTherm therefore finds a blend time per pile: the time from which the effect stays below 1 % of the response, times four, between 100 h and one year (the BoreTherm theory manual gives about 184 days for a 0.6 m pile). Beyond one month the monthly base temperatures also get the correction.
The pile temperature over the years
Model and boundary condition
How each result is derived
The Results summary shows the screening under Energy pile screening (thermal load on the pile); boretherm-cli simulate --json writes it as energyPile (SI units). Example values:
| Result | How BoreTherm derives it | Example |
|---|---|---|
| Pile resistance Rb* | multipole method, as for a borehole (concrete = grout; the pipe circle = shank spacing) | 0.0822 m·K/W |
| Pile temperature Tp | Tf − q Rb*/2: midway between fluid and pile wall; monthly mode: the monthly base Tf and base load q per metre; hourly modes: every hour | January, year 1: 6.73 − (−10.5 × 0.0822)/2 = 7.16 °C |
| Pile temperature change ΔTp | smallest and largest Tp − Tm over the whole period | −3.98 K (March of year 25) / +2.12 K (August of year 1) |
| Free thermal strain | ε = αc ΔTp | −40 / +21 µε (αc = 1.0·10⁻⁵ 1/K) |
| Free length change | ε H, H = mean active length of the piles | −0.80 / +0.42 mm (H = 20 m) |
| Fully restrained axial stress | σ = Ec αc ΔTp; + compression (heating), − tension (cooling) | −1.19 / +0.63 MPa (Ec = 30 GPa) |
| Pile inlet range (warning) | lowest field inlet temperature ≥ the pile minimum; highest ≤ the pile maximum | Tin,min 3.00 °C ≥ 0 °C |
αc and Ec are the defaults (the example does not change them); the column shows them as they follow from the result file (strain / ΔTp, stress / strain).
The example in numbers
Small office on 24 bored piles, 20 m deep, 4 m grid; double U 32 × 2.9 mm on the cage; concrete λ 1.8 W/(m·K), C 2.2 MJ/(m³·K); ground λ 2.0 W/(m·K), Tm 9.3 °C. Heating 29.2 MWh/a (seasonal performance factor SPF of the heat pump 3.8), cooling 11.7 MWh/a. Limits Tf 0 / 25 °C.
| Run | Tf,min [°C] | Tin,min [°C] | ΔTp min / max [K] | Restrained σ [MPa] |
|---|---|---|---|---|
| Example as delivered: short-time, ring model, UHTR, isothermal surface | 3.13 | 3.00 | −3.98 / +2.12 | −1.19 / +0.63 |
| Steady resistance model | 2.33 | 2.20 | −3.97 / +2.12 | −1.19 / +0.64 |
| Energy pile unticked (short-time, equivalent pipe) | 2.94 | 2.81 | – | – |
| Uniform wall temperature (UBWT) | 3.65 | 3.52 | −3.43 / +2.21 | −1.03 / +0.66 |
| Adiabatic ground surface | 1.50 | 1.36 | −5.62 / +2.00 | −1.69 / +0.60 |
- The screening hardly depends on the borehole model: it uses the monthly base. It does depend on the ground: the adiabatic surface gives −5.62 K instead of −3.98 K.
- Free length change of a 20 m pile: −0.80 mm (heating) to +0.42 mm (cooling). Fully restrained: −1.19 MPa (tension) to +0.63 MPa (compression).
- Without the energy pile box the short-time model falls back to the equivalent pipe: Tf,min 2.94 °C instead of 3.13 °C, and no screening.
Limits to keep in mind
- The screening gives the thermal input of the pile design, not the design. The real pile lies between the free and the fully restrained bound; its restraint comes from shaft friction, the toe and the structure. Axial force and mobilised friction need a load-transfer analysis by the pile designer.
- One mean pile: Tp comes from the field's mean fluid temperature and is uniform along the pile. Centre piles of a group get colder than edge piles.
- Monthly mode uses the monthly base: short peaks are not in ΔTp. Hourly loads give it hour by hour.
- The ground surface is isothermal or adiabatic over the whole field. A building over part of the field, or an unheated cellar, lies between the two.
- The ring model needs the pipes on a ring away from the axis. Pipes near the axis (rR − ro ≤ 0.1 rb, ro the pipe radius) and coaxial pipes use the equivalent pipe, with a warning.
- Not for piles: the 3D analysis (FEM) and the dynamic borehole model. Loops in series do not work with borehole sections.
- The pile inlet range gives warnings only; Size borehole length keeps the Tf limits and the optional inlet limit.
Numbers calculated with BoreTherm. Theory: BoreTherm theory manual.