HomeFeaturesExamplesTutorialsHelpTheoryVerificationPricingContact
BoreTherm / Example libraryExample 06 / 23
Worked feature example

Loads

Start from monthly office energies and peak durations, then generate an hourly office profile, a growing annual demand and a fluid-side seasonal time series.

16Boreholes
-2.41 °CMinimum mean fluid temperature
16.03 °CMaximum mean fluid temperature
5Variants compared
01 / Project

What the example does

The office loads are entered in four ways: monthly energies with peak loads (the reference), an hourly profile generated from the monthly values, a demand that grows from year to year, and a fluid-side time series of a smaller 3 × 3 field. The example shows how the load description changes the design temperatures.

Inputs

InputValue
Field16 boreholes, 4 × 4 rectangle, spacing 6.0 × 6.0 m
Boreholeslength 150.0 m, top 4.0 m below the surface, diameter 140 mm
Constructionsingle U, PE pipe 32 × 2.9 mm, shank spacing 70 mm, grout 1.60 W/(m·K)
Groundthermal conductivity 2.60 W/(m·K), heat capacity 2.20 MJ/(m³·K), surface temperature 9.0 °C, geothermal heat flux 0.060 W/m²
Fluid and flow25 % monopropylene glycol, 0.50 l/s per borehole
Loadsmonthly: heating 200 MWh, hot water 8 MWh and cooling 45 MWh per year; peaks 100 kW heating and 45 kW cooling for 6 h
Heat pumpseasonal performance factors 3.8 heating, 2.8 hot water, 5.0 cooling
Design limitsmean fluid temperature between −3.0 °C and 20.0 °C
Period25 years
Variantsmonthly energies and peaks; generated hourly profile; growth of the heating demand from year to year; fluid-side hourly time series (3 × 3 field, 120 m)

Run the example in BoreTherm

  1. Open Design → Loads. Enter monthly energies and peak loads, or use Annual total + profile to spread an annual demand over the months.
  2. Generate hourly loads builds an hourly office profile from the monthly values and a weather series; Growth / decline changes the demand year by year.
  3. Press Calculate and compare the temperature curves on Results → Mean fluid temperature and Results → Hourly temperatures.
02 / How BoreTherm calculates it

From building loads to ground loads

1 Building loadsheating 200, hot water 8,cooling 45 MWh/a2 Heat pumpground = heating (1 − 1/SPF)+ cooling (1 + 1/SPF)3 Ground loads153 MWh/a out, 54 MWh/a inpeak 74 kW out4 Time stepsmonths + peak pulses, or8,760 hours with FFT5 Yearly profilerepeated, or scaled bythe growth per year6 Superpositionload steps on the fieldg-function → TfMonthly: TfMin −2.41 °C; hourly: −3.06 °C
How the building loads of the office reach the ground.
  1. Building loadsHeating, hot water and cooling of the building, per month, with the peak load and its duration (6 h).
  2. Heat pumpThe seasonal performance factors (3.8 heating, 2.8 hot water, 5.0 cooling) convert them into ground loads: in heating the compressor work is not taken from the ground, in cooling it is added to it.
  3. Ground loadsThe ground supplies 153 MWh and receives 54 MWh a year: a net extraction of 99 MWh that cools the ground year after year.
  4. Time stepsMonthly: the month's mean load plus a peak pulse at its end. Hourly: every hour, superposed quickly with a Fourier transform (FFT).
  5. Yearly profileThe year is repeated for the design period, or scaled by a growth factor.
  6. SuperpositionEvery load change is a step on the g-function; their sum gives the fluid temperature.
03 / In BoreTherm

The example in BoreTherm

Design → Loads: monthly energies and peak loads of the office.
Design → Loads: monthly energies and peak loads of the office.
Generate hourly loads: the office profile from the monthly values.
Generate hourly loads: the office profile from the monthly values.
Growth / decline: the heating demand year by year.
Growth / decline: the heating demand year by year.
04 / Results

Calculated results

Calculated with BoreTherm for every variant of the example. Displayed values are rounded.

Loads results plotted from BoreTherm output
Chart of the BoreTherm results in the tables of this section.

Temperatures by variant

VariantBoreholesLength H [m]Tf min [°C]Tf max [°C]Rb* [m K/W]Pump [W]Design limits
monthly energies and peaks16150.000-2.41316.0260.11943,033.2within limits
generated hourly profile16150.000-3.06416.0680.11943,033.2limits exceeded
fluid-side time series (3 × 3)9120.000-0.13022.4160.1033357.7limits exceeded
growing demand16150.000-9.45816.0260.11943,033.2limits exceeded
05 / Discussion

What the example shows

The hourly profile reaches a colder minimum (−3.06 °C) than the monthly method (−2.41 °C): its cold spells last longer than the 6-hour peak of the monthly description. A demand that grows every year cools the ground further and ends far below the limit (−9.46 °C).

The generated weather and schedules are synthetic. For a real building, use hourly loads from a building simulation where they exist.