Full FEM: Materials
Full FEM ground materials per layer: thermal (Ground page values, bulk, or solid + porosity; anisotropic conductivity), hydraulic (porosity, hydraulic conductivity, specific storage), transport (dispersivity) and the pore water (conductivity, heat capacity, density and viscosity laws). Assumed values are marked.
What this page sets
The ground materials of the full 3D simulation, one row per layer of the Ground page (one row for a homogeneous ground). The layer depths stay on the Ground page; the 2D design and the Simple FEM keep using the Ground page values. Every edit is one undo step.
- Thermal: Values per layer: Ground page (the bulk λ and C of the Ground page, isotropic: the default), Bulk (own bulk values) or Solid + porosity (the solid's values; the bulk follows with the porosity n and the pore water: λ = λs1−n λwn, C = (1−n)(ρc)s + n(ρc)w). λ horizontal and λ vertical make an anisotropic ground. Check shows ✓ when the bulk values equal the Ground page and “≠ Ground page” when the 3D simulation computes with other ground properties than the 2D design.
- Hydraulic (fully coupled TH): porosity, hydraulic conductivity K horizontal / vertical (stored as the permeability k at the reference temperature), specific storage; tick a layer for its own values. A sand–gravel aquifer has K of about 10⁻⁴ to 10⁻² m/s, clay below 10⁻⁸ m/s.
- Transport (fully coupled TH): longitudinal and transverse thermal dispersivity.
- Fluid: the pore water: thermal conductivity λw, heat capacity, the density law (Linear in temperature = buoyancy) and the viscosity law (Vogel for pure water 0–100 °C).
Values in italics are assumed (pre-filled or derived); the banner and the report list them. Replace them with site data before relying on a coupled result.
Guided example: 13 Full FEM with groundwater flow (TH) (Hydraulic and Fluid tabs).
Step-by-step workflows · Menus and keyboard

| Control | Meaning / action | Unit | Range / choices | Example value |
|---|---|---|---|---|
| Thermal conductivity: | Thermal conductivity of the pore water (0.58 W/(m·K) at 10 °C). | W/(m·K) | 0.1 to 5 | 0.58 |
| Volumetric heat capacity: | Volumetric heat capacity (ρc)w of the water: its share of the bulk heat capacity and the heat the groundwater carries. The same value as in the groundwater group of the Ground page. | MJ/(m³·K) | 0.5 to 10 | 4.18 |
| Density: | Select one of the listed alternatives. | Constant (no buoyancy) / Linear in temperature (buoyancy) | ||
| Viscosity: | Select one of the listed alternatives. | Constant / Exponential in temperature / Vogel (pure water, 0-100 °C) | ||
| Reference density: | Water density at the reference temperature. | kg/m³ | 500 to 2000 | 999.7 |
| Reference temperature: | Reference temperature T0 of the laws (also the temperature K is shown at). | °C | -20 to 150 | 10 |
| Reference viscosity: | Dynamic viscosity at the reference temperature. | mPa·s | 0.01 to 1000 | 1.306 |
| Thermal expansion: | Thermal expansion coefficient β of the linear density law. | ×10⁻⁴ 1/K | 0 to 10 | 0.88 |
| Viscosity exponent: | Exponent f of the exponential viscosity law mu = mu0 exp(f (T - T0)) (water: about -0.0265). | 1/K | -1 to 1 | -0.0265 |
| Reference temperature: | Reference temperature T0 of the laws (also the temperature K is shown at). | °F | -4 to 302 | 50 |