2.1 Latin symbols
| Symbol | Quantity | Unit |
|---|---|---|
| borehole spacing (centre to centre) | m | |
| volumetric heat capacity of the ground, | J/(m³ K) | |
| specific heat capacity of the fluid | J/(kg K) | |
| buried depth of the borehole top | m | |
| , | horizontal distance between boreholes (segments) | m |
| inner pipe diameter; hydraulic diameter | m | |
| exponential integral | – | |
| Darcy friction factor | – | |
| thermal response factor (g-function) | – | |
| active borehole length | m | |
| convective heat transfer coefficient | W/(m² K) | |
| segment-to-segment response factor | – | |
| multipole order | – | |
| total active length of the field, | m | |
| heat capacity flow (one borehole unless stated) | W/K | |
| number of boreholes; number of time steps | – | |
| , , | Nusselt, Prandtl and Reynolds numbers | – |
| pump electric power | W | |
| heat rate of the field (+ injection) | W | |
| heat rate per metre of borehole (+ injection) | W/m | |
| geothermal heat flux | W/m² | |
| local borehole thermal resistance, fluid to borehole wall | m K/W | |
| effective borehole resistance (with leg-to-leg short-circuit) | m K/W | |
| internal (leg-to-leg) resistance | m K/W | |
| pipe resistance: convection + wall + contact, one pipe | m K/W | |
| , , | borehole radius; inner and outer pipe radius | m |
| shank spacing (opposite legs); integration variable | m; 1/m | |
| , , | borehole-wall, mean fluid and undisturbed ground temperature | °C |
| , | fluid temperature entering and leaving the field | °C |
| mean ground surface temperature | °C | |
| , , | time; Eskilson's characteristic time; peak duration | s |
| volume flow | m³/s |
2.2 Greek symbols and subscripts
| Symbol | Quantity | Unit |
|---|---|---|
| thermal diffusivity of the ground, | m²/s | |
| dimensionless pipe resistance | – | |
| absolute pipe roughness | m | |
| pump efficiency; Hellström's short-circuit parameter | – | |
| , , , | conductivity of ground, grout, pipe wall and fluid | W/(m K) |
| dynamic viscosity of the fluid | Pa s | |
| density of the fluid | kg/m³ | |
| conductivity contrast | – | |
| load-aggregation weight | – | |
| b, f, p | borehole wall, fluid, pipe | |
| ext, inj | extraction (heating), injection (cooling) | |
| UHTR, UBWT | uniform heat transfer rate, uniform borehole-wall temperature | |
| UHF | uniform heat flux (Rb* formula) |
| Symbol | Quantity | Unit |
|---|---|---|
| , | Darcy velocity (specific discharge); heat-transport velocity | m/s |
| Péclet number | – | |
| flow direction; borehole azimuth (from +x towards +y) | rad | |
| borehole tilt from the vertical | rad | |
| vertical extent of the active length | m | |
| , | local resistance of segment i (UFT); parallel resistance of the field | m K/W |
| , , | conductances of the down- and up-going channels to the wall and between them | W/(m K) |
| , | combined short-time response; capacity correction | – |
| , | pressure drop of a string; minor-loss coefficient | Pa; – |
| clearance of a position in the site plan | m | |
| undisturbed ground temperature of a thermal response test | °C | |
| time constant of the borehole resistance term (TRT) | s | |
| , | effective number of observations; lag-1 autocorrelation of the residuals | – |
| Fourier number | – |
2.3 Conventions
- Sign. A heat rate is heat injected into the ground (cooling mode); is heat extracted (heating mode). The classic monthly method and part of the literature use the opposite sign; imported data are converted.
- Heat rate per metre. with the total active length.
- Months. Twelve equal months of 730 h each, as in the classic monthly method; results are given at the end of each month. Month index 0 is January.
(2.1)
- Energies in MWh per month are converted to mean powers with the 730 h month: .
- Units. SI throughout; load inputs in other units (energies in MWh, peak powers in kW, durations in h) are marked with their unit.