3.1 Assumptions
The ground is a homogeneous, isotropic semi-infinite solid with constant thermal properties, or a stack of horizontal layers (Section 3.3, Chapter 11). Heat is transported by conduction and, optionally, by a uniform horizontal groundwater flow (Chapter 12); freezing of pore water is not modelled. The ground surface is held at its undisturbed temperature; the boreholes are vertical unless inclined (Chapter 13). Because the heat equation is then linear, the temperature response to any load history is the superposition of step responses; all of BoreTherm's temperature calculations rest on this property.
3.2 Diffusivity and undisturbed temperature
The undisturbed ground temperature seen by a borehole is the mean over its length of the initial temperature field . As in the classic monthly method, it is evaluated at half the borehole length:
The classic monthly method has no buried-depth input, and (3.2) deliberately uses rather than , as its published manual states (the value of 10.08 °C of the manual's worked example is reproduced). For a field of unequal lengths is the mean length. For the example ( = 9 °C, = 0.06 W/m², = 2.6 W/(m K), H = 150 m) (3.2) gives = 10.73 °C. Since grows with , the maximum fluid temperature can increase with the borehole length (Section 9.4).
3.3 Layered ground
The ground can be described as horizontal layers from the surface down, each with a thickness , a conductivity and a heat capacity ; the last layer extends to infinity. In the effective-property model (the default for layered ground) the layers enter every part of the calculation through thickness-weighted means over the active length of the borehole:
where is the part of layer inside . Around a borehole the heat flows radially, through all layers side by side, so the layers act as parallel conductances and the arithmetic mean is the consistent choice; stored heat adds in the same way. replaces in (3.6) and in the multipole ground conductivity, replaces in and the g-function. The means are evaluated as , so that equal layers and a single layer reproduce the homogeneous ground bit for bit. The undisturbed temperature has two models. The mid-depth model (default) is (3.2) with :
It is exactly (3.2) for a homogeneous ground. The active-length average follows the geotherm through the layers: the geothermal flux is vertical and crosses the layers in series, so the undisturbed temperature at depth is with the series resistance from the surface, and is its mean over the active length:
R is piecewise linear, so the trapezoidal rule over the pieces of the layers inside is exact. For a homogeneous ground (3.5) gives , the convention of an open-source sizing tool; it accounts for the buried depth and for poorly conducting cover layers, which (3.4) ignores. Sizing evaluates , and again at every trial length, and the g-function cache (Section 9.3) adds a node wherever crosses a layer interface, where these values have a kink.
| Layer | Depth [m] | [W/(m K)] | [MJ/(m³ K)] |
|---|---|---|---|
| Clay / silt, water saturated | 0 – 8 | 1.7 | 2.4 |
| Sand, water saturated | 8 – 25 | 2.4 | 2.5 |
| Claystone / siltstone | 25 – 80 | 2.2 | 2.3 |
| Limestone | 80 – 125 | 2.8 | 2.2 |
| Granite | 125 – ∞ | 3.4 | 2.4 |
For this ground and the borehole of the example (D = 4 m, H = 150 m), (3.3) gives = 2.621 W/(m K) and = 2.315 MJ/(m³ K), close to the homogeneous example's 2.6 and 2.2. The mid-depth model gives = 10.72 °C, the active-length average 11.07 °C: the clay cover and the buried depth raise the temperature below them. Sized to the same limits, the field needs 140.3 m per borehole with the active-length average, 143.1 m with the mid-depth model and 143.7 m on the homogeneous ground; at the sized lengths less of the granite lies inside the active length, so is lower than at 150 m.
The effective model ignores the vertical heat flow between the layers and that a conductive layer takes more than its share of the heat. The segmented model splits the boreholes at the layer interfaces and gives each segment pair the properties of its layers in the finite line source; it keeps , and as the reference values and changes only the g-function. Chapter 11 describes it together with the borehole sections (diameter, grout and insulation along the depth, independent of the layers) and the uniform-fluid-temperature boundary condition that goes with them.
3.4 Superposition
With as the initial state, the borehole-wall temperature for a piecewise-constant heat rate per metre applied from is
where is the step response defined in Chapter 4. Chapters 8 and 9 apply (3.6) on monthly and hourly time steps.