HomeFeaturesExamplesTutorialsHelpTheoryVerificationPricingContact
Theory manual

Appendix A. Conventions of the classic monthly method

The table summarises how BoreTherm's formulation relates to the conventions of the classic monthly method. Each item was confirmed against the method's published manual and its worked examples, either by the manual's statements or by reproducing the numbers printed there.

Table 67. BoreTherm and the conventions of the classic monthly method.
ItemBoreThermClassic methodEvidence
Undisturbed temperature(3.2)same (H/2, no D)manual; worked example 10.08 °C reproduced
Monthly superposition, month-end values, 730 h months(8.2), (8.3)sameworked example: 0.08 K rms with D ≈ 4 m
Peak pulse at month end, replaces base, energy not added(8.4)samemanual
Peak g-functionfield g (default); (8.5) (option)asymptote (8.5)back-calculation, residual ≤ 0.0024
Rb* uniform heat flux(5.21) (default); fixed Rb* (option)same; constant valuesworked examples; manual's Rb* table ≤ 0.09 %
Ra definition(5.16)same (2Tf/q12)Hellström eqs. 8.16–8.21; manual
ConvectionGnielinski + blend (default); (5.5) (option)4.0 / Colburn (5.5)worked example; manual's Rp table ≤ 0.1 %
Multipole orderJ = 3 (0–10)1–10manual
Double-U legs, flowdown-legs adjacent; Re with half the flowsamemanual; Rb* table
Sizing periodall years (default); last year (option)last yearmanual; Ahmadfard & Bernier 2019
Hourly peaksloads as givenlast tp hours of the monthmanual
Tin/Tout(8.12)same (sign converted)manual
g-functionFLS at run time, any layoutlibrary (797 fields, Eskilson SBM)manual

Table 68 summarises the measured agreement with published results of the classic monthly method, in BoreTherm's default mode and with the classic-method preset (Section 9.4; the imposed Rb* of the Ahmadfard & Bernier cases is set as a fixed effective resistance in both modes). All values were computed with the same BoreTherm version.

Table 68. Measured agreement with published results of the classic monthly method. Note: in the default mode the Ahmadfard & Bernier lengths are compared with the classic method's one-year result for case 3 (112 m), because BoreTherm then checks every year.
CaseClassic methodBoreTherm defaultBoreTherm classic preset
Linden worked example: Rp per pipe [m K/W]0.27280.2890 (+5.9 %)0.2727 (−0.04 %)
Linden: Rb / Ra [m K/W]0.2088 / 0.66250.2135 / 0.67990.2088 / 0.6629 (+0.06 %)
Linden: Rb* at 50 m [m K/W]0.21000.2146 (+2.2 %)0.2100
Linden: 48 monthly base Tf, max / rms dev. [K]–0.153 / 0.084 (aligned Rb*)0.153 / 0.084
Linden: required length (sizing example) [m]82.5882.96 (+0.5 %)82.32 (−0.3 %)
Manual's Rb* against flow, 10 rows, max. dev.–2.1 %0.09 %
Ahmadfard & Bernier cases 1a–4, 7 lengths59.8–123.0 mwithin 1.0 % (see note)within 1.3 %
Ahmadfard & Bernier case 3 (10 years) [m]87.8110.93 (all years)88.87 (+1.2 %)
Tutorial example 2 of the manual (Re ≈ 2750) [m]129133.98 (+3.9 %)128.86 (−0.1 %)