Source, inputs and purpose
Source. Kavanaugh, S. and Rafferty, K. (2014). Geothermal Heating and Cooling: Design of Ground-Source Heat Pump Systems. ASHRAE, Atlanta. Example 3.2, pp. 69–71, with the temperature penalty of Example 3.5, pp. 84–87.
Inputs and reference results are taken from the cited publication; BoreTherm results were calculated with BoreTherm on the project rebuilt from those inputs; differences are explained below.
What the example checks
A strongly cooling-dominated building on a closely spaced field. The book first assumes a small long-term penalty, then calculates it and iterates the length. The comparison checks BoreTherm’s field interference where the ground warms year after year.
Inputs
Values marked Assumption are not given in the book and were chosen for the BoreTherm project; the others are the book’s, with the section or page.
| Input | Value | Source |
|---|---|---|
| Block loads | 300,000 Btu/h cooling (87.92 kW), 180,000 Btu/h heating (52.75 kW) | Ex. 3.2 |
| August part-load factor | 0.28 | Ex. 3.2 |
| Heat pump efficiency (fixed) | EER 14.1 Btu/Wh (COPc 4.13), COPh 4.1 | Ex. 3.2 |
| Equivalent full-load hours | 1,220 h cooling, 590 h heating | Ex. 3.2 |
| Field | 5 × 5 boreholes at 20 ft (6.1 m), 127 mm, 1 in. DR 11 single U | Ex. 3.2 |
| Ground | 2.42 W/(m·K), diffusivity 1.0 ft²/day (2.25 MJ/(m³·K)), 18.33 °C | Ex. 3.2 |
| Grout | 1.73 W/(m·K) | Ex. 3.2 |
| Fluid and flow | water, 2.98 gpm per U-tube (4.70 L/s in total) | Ex. 3.2 |
| Borehole resistance | 0.104 m·K/W, imposed as Rb* | Ex. 3.2 |
| Design period | 10 years | Ex. 3.2 |
| Length per borehole in the project | 97.5 m (the book’s iterated 320 ft) | p. 87 |
| Sizing criterion | mean fluid temperature ≤ 32.22 °C (90 °F, mean of the entering 85 °F and leaving 95 °F) | Assumption |
| Monthly loads | August cooling 18.32 MWh, the rest of the year by an office shape; heating by approximate Atlanta degree days | Assumption |
| Peak months | 87.92 kW cooling in August, 52.75 kW heating in January, 4 h | Assumption |
Run the example in BoreTherm
- Open the Atlanta reference project from the examples folder (File → Open).
- Press Calculate to see the temperatures at the book's 97.5 m.
- Press Size borehole length and open Results → Required borehole length.
Two ways to the length
- Same loadsThe block loads, full-load hours and efficiencies of Example 3.2.
- PenaltyThe book iterates a long-term penalty from ring temperatures.
- Field responseBoreTherm's g-function of the 25 boreholes includes all interaction.
- LengthCooling sets the length in both.
The example in BoreTherm
Calculated results
Displayed values are rounded. Differences are BoreTherm relative to the book unless stated otherwise.
| Quantity | Book | BoreTherm | Difference |
|---|---|---|---|
| Cooling length, iterated penalty (Ex. 3.5) | ≈ 2,438 m (25 × 320 ft) | 2,670 m (25 × 106.8 m) | +9.5 % |
| Same, BoreTherm’s classic-method sizing options | ≈ 2,438 m | 2,658 m (25 × 106.3 m) | +9.0 % |
| Cooling length with the assumed penalty of 2 °F | 2,141 m (p. 71) | 2,670 m | +24.7 % |
| Maximum mean fluid temperature at 97.5 m | criterion 32.22 °C | 33.43 °C | 1.2 K above the criterion |
| Cooling length over 20 instead of 10 years | – | 2,923 m (25 × 116.9 m) | +20 % against 2,438 m |
Why the results differ
Why BoreTherm is longer here
About 110 MWh of net heat goes into the ground every year, into a field whose spacing is only about 6 % of its depth. The book’s calculated penalty (about 2.8 K, plus about 0.8 K from the annual load through the ground resistance) underestimates the rise in ground temperature that the field’s g-function gives over ten years. In the two moderately unbalanced Kavanaugh cases (Ottawa and St. Louis) BoreTherm is within −8 % to +3 % of the book; in this strongly unbalanced case it is the longer design. This is the clearest example in the series of why computing the interference, instead of taking a tabulated penalty, changes the answer.
Notes on the book’s numbers
- The condenser heat is printed as 372,000 Btu/h in one place and 372,600 Btu/h in the flow and length lines.
- Example 3.5 calculates its ring temperatures over 20 years and one month, but stores the heat over ten years and calls the result the ten-year penalty. The project keeps the ten-year period of Example 3.2; over 20 years BoreTherm needs 20 % more than the book’s iterated length.