Source, inputs and purpose
Source. Chiasson, A.D. (2016). Geothermal Heat Pump and Heat Engine Systems: Theory and Practice. Wiley / ASME Press. §5.5.6: Example 5.4b, pp. 164–166, with its result sheet Fig. E.5.4b (p. 166); Example 5.5 a–c, p. 167; Example 5.6, pp. 167–169, with Fig. E.5.6 (p. 168).
Inputs and reference results are taken from the cited publication; BoreTherm results were calculated with BoreTherm on the project rebuilt from those inputs; differences are explained below.
What the example checks
The local borehole resistance, from the fluid to the borehole wall, of a single U-tube: the base case, a better grout, the legs moved against the borehole wall, and both. This is the quantity that connects the fluid temperature to the ground model, so it is checked on its own.
Inputs
Values marked Assumption are not given in the book and were chosen for the BoreTherm project; the others are the book’s, with the section or page.
| Input | Value | Source |
|---|---|---|
| Pipe | DN25 SDR 11 HDPE: outer 33.401 mm, inner 27.328 mm, 0.4 W/(m·K) | Fig. E.5.4b |
| Leg position, Ex. 5.4b | evenly spaced, 31.75 mm from the borehole centre (shank spacing 63.5 mm) | Fig. E.5.4b |
| Borehole | 127 mm, 75 m | Fig. E.5.4b |
| Fluid and flow | water at 5 °C, 40 L/min | Fig. E.5.4b |
| Grout and ground | grout 0.73 W/(m·K), ground 1.8 W/(m·K) | pp. 166–167 |
| Ex. 5.5 a / b / c | grout 1.50 W/(m·K) / legs against the borehole wall (shank spacing 93.6 mm) / both | p. 167 |
| Resistance model | multipole, order 3 | Assumption |
| Depth, ground heat capacity and temperature, loads | illustrative only; the local resistance does not depend on them | Assumption |
Run the example in BoreTherm
- Open the single-U resistance reference project from the examples folder (File → Open).
- Open Design → Borehole cross-section; the resistance panel updates as you change the grout or the shank spacing.
- Press Parametric study to run the stored study of the four cases.
The resistance chain of Example 5.4b
- Flow regimeThe Reynolds number agrees with the book's sheet (20,453).
- ConvectionThe heat transfer coefficient at the pipe wall.
- Pipe resistanceConduction through the HDPE wall plus the convection film.
- MultipoleConduction in the grout between the two legs and the borehole wall.
- RbWithin 0.4 % of the book in all four cases.
The example in BoreTherm
Calculated results
Displayed values are rounded. Differences are BoreTherm relative to the book unless stated otherwise.
Local borehole resistance Rb in m·K/W.
| Quantity | Book | BoreTherm | Difference |
|---|---|---|---|
| Ex. 5.4b: base case | 0.1802 | 0.1799 | −0.2 % |
| Ex. 5.5a: grout 1.50 W/(m·K) | 0.1120 | 0.1116 | −0.4 % |
| Ex. 5.5b: legs against the wall | 0.1242 | 0.1239 | −0.2 % |
| Ex. 5.5c: both | 0.0902 | 0.0898 | −0.4 % |
| Reynolds number, Ex. 5.4b | 20,453 | 20,457 | 0.0 % |
Why the results differ
Single U: the validation
Both the book’s tool and BoreTherm use a multipole-type borehole resistance, and they agree within 0.4 % in all four single-U cases. The three variants of Example 5.5 are stored in the project as a parametric study (grout conductivity × shank spacing), so all four values come from one run. With the line-source approximation (multipole order 0) BoreTherm’s values are 0.4–3.5 % higher.
A note on the book’s inputs
The text of Example 5.4b gives a 125 mm borehole and 10 L/min, but its result sheet and its result use 127 mm and 40 L/min; the book’s 0.1802 is reproduced only with the sheet’s inputs. With 10 L/min BoreTherm gives 0.1846 m·K/W at a Reynolds number of 5,114.
Double U (Example 5.6): an inconsistency in the book
The double-U example is not presented as a match. The book’s 0.086 m·K/W is an effective resistance (its Eq. 5.39, p. 162, includes the short-circuit term between the legs), not the local resistance compared above. Its definition of the pipe spacing is ambiguous (between pipe edges or between centres), and its grout term looks too small. BoreTherm’s effective Rb* and local Rb will be documented against the 0.086 m·K/W.
| Reading of the 75 mm spacing | Local Rb [m·K/W] | Effective Rb* [m·K/W] | Rb* vs book 0.086 |
|---|---|---|---|
| Centre-to-centre, opposite legs (as stated; used in the project) | 0.1419 | 0.1517 | +76 % |
| Centre-to-centre, adjacent legs | 0.0878 | 0.0969 | +13 % |
| Between pipe edges, opposite legs | 0.0841 | 0.0932 | +8 % |
Whichever reading is taken, the book’s value cannot be reproduced from its own inputs, so the double U is shown here for transparency only. The single-U results above are the validation.