1.1 Purpose and scope

This reference documents the physical models, equations and numerical methods of BoreTherm, a desktop tool for designing fields of vertical borehole heat exchangers (BHE) for ground-source heat pumps. It is written for engineers who check the results or build on the methods, and for reviewers who need to trace a result back to its equation. The operation of the program is not described here.

BoreTherm computes, for a given borehole field, heat exchanger and load:

1.2 Relation to the classic monthly method

BoreTherm follows the classic monthly method of borehole design (Hellström & Sanner 1994): temporal superposition of g-function step responses with monthly base loads, a rectangular peak pulse at the end of every month, equal 730-hour months, Hellström's effective borehole resistance and the multipole method. The classic monthly conventions were checked against the method's published manual and by reproducing the numbers of its worked examples; the evidence is summarised in Appendix A. Where BoreTherm deliberately differs from the classic conventions, the difference is stated and, where useful, a compatibility option exists (Section 1.4).

The main methodological difference is the g-function. The classic method interpolates in a library of about 800 pre-computed configurations obtained with Eskilson's numerical model (vertical boreholes, B/H = 0.02–0.5, regular layouts only). BoreTherm computes the g-function of the actual field at run time with the semi-analytical finite line source method of Cimmino & Bernier (2014), so irregular layouts, unequal lengths and any spacing are handled directly.

1.3 What BoreTherm adds

1.4 Compatibility options for the classic monthly method

Four options reproduce the conventions of the classic monthly method where they differ from BoreTherm's defaults. Every default keeps BoreTherm's behaviour. The options are stored with the project (a project without them gets the defaults) and can be set in the program.

Table 1. Compatibility options for the classic monthly method.
OptionDefault / classicEffect
Fixed effective resistance0 (computed) / > 0Constant Rb* at every length (the classic “constant values”); Rb, Ra and the hydraulics are still computed (Section 5.7).
Convection modelGnielinski / classicNu = 4.0 laminar, 0.023Re0.8Pr1/3 turbulent, no transition blend (Section 5.2).
Peak responsefield g-function / asymptotePeak pulses use Eskilson's single-borehole asymptote instead of the field g-function (Section 8.2).
Last year onlyoff / onSizing checks the limits in the last simulated year only (Section 9.4).

The classic-method preset sets the convection, the peak response and last-year sizing to the classic monthly conventions; the Rb* formula and the UBWT g-function follow the classic conventions already by default, and a fixed Rb* is a separate input. With the preset BoreTherm reproduces the borehole resistances printed in the method's published manual to 0.06 % and the required lengths of seven published cases computed with the classic method to 1.3 % (Table 68 in Appendix A).

1.5 Document conventions

Equations are numbered by chapter. Symbols are listed in Chapter 2. Units are SI unless stated; temperatures are in °C. The numerical examples use the ground, borehole and fluid of the program's example project: λ = 2.6 W/(m K), Cv = 2.2 MJ/(m³ K), H = 150 m, rb = 70 mm, D = 4 m, B = 6 m, single-U PE 32 × 2.9 mm, 25 % monopropylene glycol at 0.5 l/s per borehole. All numbers in this manual were computed with BoreTherm.

Chapters 1–10 describe the method BoreTherm shares with the classic monthly method and its classical extensions. Chapters 11–17 describe the further models: the segmented layered model with borehole sections, groundwater flow, inclined and unequal boreholes, connection networks, the short-time borehole model, site plans and the evaluation of thermal response tests. Chapter 18 to Chapter 29 describe the dynamic borehole model, borehole thermal energy storage, energy piles, the thermal plume, the finite element models, co-simulation, the load tools and input checks, the heat pump, the borefield costs and the heating-system comparison. Each of the extensions reduces exactly to the classical model when it is not used: a project that does not use one of these features gives bit-identical results.