Borehole layouts
Explore nine head patterns, from a single borehole to concentric rings and custom coordinates.
Real BoreTherm projects, the calculation step by step, screenshots of the program, results and an engineering discussion. Open a case and see how the pieces fit.
23 examples
Explore nine head patterns, from a single borehole to concentric rings and custom coordinates.
Compare directional, radial, fan and arc arrangements, with axis-clearance warnings.
Compare U-pipe and coaxial designs, depth sections and an insulated interval.
See how layers, the geothermal gradient and groundwater change the same office design.
Compare built-in mixtures, custom properties, pump power and freezing margins.
Move from monthly demand to hourly profiles, yearly growth and seasonal operation.
Follow 25 years of fluid temperatures and examine a deliberately undersized field.
Find the required active length, including a field with unequal borehole lengths.
Compare layout rankings by total length, installation cost and lifecycle cost.
Inspect parallel and series networks, pressure-balanced strings and pumping power.
Check an L-shaped plot, exclusion zones and setbacks. Compare four fill patterns.
Import, screen and fit a response test, then apply the result to a saved design.
Compare one-at-a-time sensitivity with a grid of ground conductivity and heating demand.
Inspect design percentiles, probability of meeting limits and sensitivity correlations.
Compare analytical and full FEM results, coupled groundwater flow and 3D sizing.
Map temperature changes and inspect threshold extents and property-line clearances.
Follow seasonal charging, reversed discharge flow, ring temperatures and energy recovery.
Compare simple rates and an itemized estimate with contingency and VAT.
Compare seven heating systems with stated cost, performance and emissions assumptions.
Run the bundled heat-pump FMU and explore coupled sizing and Modelica export.
Inspect charts, CSV data and native PDF, HTML and Markdown reports.
Pack a project with its linked plan, unpack it and validate the restored inputs.
Run a CLI batch, save parameters through the C API, and compare display units.
Search by feature or choose a different topic.
Nine worked examples from four published design books, rebuilt as BoreTherm projects. Each page cites the source, marks the assumptions and explains every difference.
9 references · R1–R9 · Sizing 4 · Heat pump selection 1 · Borehole resistance 1 · Hydraulics 2 · Energy piles 1
Sources: Kavanaugh & Rafferty (2014), ASHRAE; Chiasson (2016), Wiley / ASME Press; Bonin (2015), Routledge; Laloui & Rotta Loria (2020), Academic Press. Inputs and reference results are taken from the cited publications; BoreTherm results were calculated with BoreTherm.
A 5 × 4 field for a heating-dominated office, sized against the ASHRAE method, with a heat pump candidate check.
A 2 × 5 field for the north cluster of an office, limited by cooling, with the heating length as a second check.
A dense 5 × 5 field under a strong cooling imbalance, where the calculated interference makes BoreTherm the longer design.
A heating-dominated 48-borehole field sized from monthly loads and 6-hour peaks, with limits on the heat pump entering temperature.
Four catalogue heat pumps checked against a house on four double-U boreholes: capacity, brine flow, buffer and pump head.
The local borehole resistance of a single U for four grout and pipe positions; the double-U example is under review.
Head loss of five parallel U-tubes with glycol in transitional flow, plus header and coil, to the required pump head.
Head loss to the farthest borehole of a reverse-return field with water, split into U-tube and header losses.
The fluid temperature change of one 19.2 m energy pile after eight months, against infinite line and cylinder sources.